Fortune Telling Collection - Comprehensive fortune-telling - What are the troubleshooting methods of computer wire stripping machine?

What are the troubleshooting methods of computer wire stripping machine?

1. displays "Err0 1". Cut a few threads and stop automatically: the gap between discharge wheels is too large. First, clamp a wire on the wheel, and turn the knob for adjusting the wheel clearance downwards until the broken light at the wheel goes out, and then turn it downwards by 2 digits.

2. Press Run once to stop immediately and display "Err02": the line segment is thick, the speed is too fast, and the adjustment speed is slow, so try again; The voltage is insufficient and an independent regulated power supply is needed; There is dust on the cutter head sensor or the positioning iron plate of the cutter head sensor is misplaced, which needs to be cleaned or repositioned.

3. "Err02" appears silently during operation: the fuse tube is broken, replace it and try again. If it is damaged again, one of the transmission plates needs to be replaced.

4. "Err03" appears on the display screen: data input error, press the function key to browse once and change the wrong data. (Maybe the thread end is longer than the thread end)

5. The machine moves once according to the running cutter head, without feeding the wire, and "Err04" is displayed: the quantitative data is zero, so quantitative data needs to be entered; The output data has reached the highest value, and the output needs to be cleared. Press Output, and then press Delete.

6. Scalp peeling and tilting: adjust the catheter seat to make the center of the catheter and the center of the blade in the same straight line; The catheter is too far away from the knife edge, and the adjustment becomes closer; Whether the catheter is too large, need to replace the appropriate catheter.

7. There is inclination after the tail skin is peeled off: whether the catheter relay is beating normally. If it can't jump, it is necessary to replace the relay or check whether the relay is in poor contact (emergency measures: the position of the catheter can be moved in the direction of the wire feeding wheel, so that the distance from the catheter mouth to the blade is greater than the length of the wire tail).

8. Thread end can't be separated: check the cutting depth of thread end and adjust the thread diameter to become larger; The pressure of the feed wheel is not enough, so it is necessary to adjust the gap and pressure of the feed wheel, and the gap will decrease or the pressure will increase.

9. The tail cannot be peeled off: check the cutting depth of the tail and adjust the diameter of the line to become larger; The pressure of the wind turbine is not enough, so it is necessary to adjust the clearance and pressure of the wind turbine, and the clearance is reduced or the pressure is increased.

10. The conductor embossing is too heavy: firstly, please judge whether the embossing comes from the incoming wheel or the outgoing wheel, and lower the corresponding pressure knob or increase the clearance knob. (Replace the silicone wheel if necessary)

1 1. Several copper cores were cut off when stripping the wire ends: the wire diameter data was reduced one by one until the copper cores were not damaged.

65438+ may have entered data with decimal point and need to be cleared; The pulse equivalent needs to be adjusted. Check whether the motor synchronous belt is missing teeth or too loose.

13, the total length is not in line with the actual situation, and there is a solid line.